On Fri, 22 Feb 2013, Ignacio Diaz-Emparanza wrote:
I am seeing a problem with models saved in the session icon view and
subsamples. From the GUI open a data file with a full sample of e.g. 2000
obs. and run a first OLS (hsk in my case) command with 1-1000 obs and a
second OLS with 1001-2000 saving them to the session. Now with with a the
current sample
being the last one, 1001-2000, go to the icon view and open the first model.
In the model window select Edit/Modify model and remove a regresor, then the
new model is not estimated with its corresponding sample 1-1000, but with the
current sample 1001-2000.
In that situation (calling Modify model) you should now get a
dialog box asking if you want to restore the sample on which
the model was estimated. If Yes we go ahead; if No we abort
the Modify model procedure.
This is in CVS and snapshots.
Allin