I am seeing a problem with models saved in the session icon view and
subsamples. From the GUI open a data file with a full sample of e.g.
2000 obs. and run a first OLS (hsk in my case) command with 1-1000 obs
and a second OLS with 1001-2000 saving them to the session. Now with
with a the current sample
being the last one, 1001-2000, go to the icon view and open the first
model. In the model window select Edit/Modify model and remove a
regresor, then the new model is not estimated with its corresponding
sample 1-1000, but with the current sample 1001-2000.
This is with the current CVS version of gretl on Ubuntu Linux 12.04
--
Firma Arista
*Ignacio Díaz-Emparanza*
Zuzendaria/Director
ignacio.diaz-emparanza(a)ehu.es <mailto:ignacio.diaz.emparanza@ehu.es>
94 6013732
*EKONOMIA APLIKATUA III SAILA (EKONOMETRIA ETA ESTATISTIKA)/
DEPARTAMENTO DE ECONOMÍA APLICADA III (ECONOMETRÍA Y ESTADÍSTICA)
UPV/EHU*
Avda. Lehendakari Aguirre, 83 | 48015 BILBAO
*T.: +34 946013740* | *F.: +34 946013754*
*www.ea3.ehu.es* <
http://www.ea3.ehu.es>
ERNE! Baliteke mezu honen zatiren bat edo mezu osoa legez babestuta
egotea. Mezuak badu bere hartzailea. Okerreko helbidera heldu bada
(helbidea gaizki idatzi, transmisioak huts egin) eman abisu igorleari,
korreo honi erantzunda. Kontuz! Mezua ez bada zuretzat, ez erabili, ez
zabaldu beste inori, ez kopiatu eta ez baliatu.
¡ATENCIÓN! Este mensaje contiene información privilegiada o confidencial
a la que sólo tiene derecho a acceder el destinatario. Si usted lo
recibe por error le agradeceríamos que no hiciera uso de la información
y que se pusiese en contacto con el remitente.
E-mail hau inprimatu baino lehen egiaztatu inprimatzeko beharra.
Antes de imprimir este e-mail piense bien si es necesario hacerlo.