That is the reason why I see no serious need to change the default
value: It's already possible to set the lambda value as wished.
Nevertheless, to add Ignacio's references to the manual would be a good
idea though.
Artur
Am 14.10.2016 um 17:15 schrieb Riccardo (Jack) Lucchetti:
On Fri, 14 Oct 2016, Ignacio Diaz-Emparanza wrote:
> The 'hpfilt' function we have in gretl has a fixed value for lambda,
> and the defaults we have do not seem to be the better.
Actually, you can call hpfilt with a second optional parameter:
<hansl>
open fedstl.bin
data indpro
logs indpro
series hpt_l_indpro = l_indpro - hpfilt(l_indpro)
series hpt_l_indpro2 = l_indpro - hpfilt(l_indpro, 129600)
</hansl>
-------------------------------------------------------